Description |
Item target |
Specifications |
Wind Turbine Input Characteristics |
Open circuit voltage |
≤ 1 00 V DC |
Charging current |
20A _ M ax |
|
Unloading voltage |
31 . 5 VDC ± 0 . 2VDC |
|
Recovery voltage after unloading |
27 . 5 VDC ± 0 . 2VDC |
|
Unloading resistance value |
1.7Ω ± 15% |
|
Input connection method |
Terminals |
|
PV module input characteristics |
Open circuit voltage |
≤ 50 V DC |
Charging current |
20A _ M ax |
|
Input connection method |
Terminals |
|
Charge and discharge characteristics |
Rated battery voltage |
24V _ DC |
Controller efficiency |
≥ 95 % |
|
Equalizing voltage |
28 . 2 VDC ± 0 . 2VDC |
|
Float voltage |
27 . 6 VDC ± 0 . 2VDC |
|
Low battery alarm |
22 . 0 VDC ± 0 . 2VDC |
|
Battery low voltage protection |
21 . 6 VDC ± 0 . 2VDC |
|
Battery low voltage recovery |
26 . 0 VDC ± 0 . 2VDC |
|
Overcharge protection voltage |
28 . 8 VDC ± 0 . 2VDC |
|
Battery high voltage alarm |
30 . 0 VDC ± 0 . 2VDC |
|
Battery high voltage protection |
31.5 VDC ± 0.2 VDC ( Turn off the output after 60 s ) |
|
Battery high voltage recovery |
31 . 5 VDC ± 0 . 2VDC |
|
AC output characteristics |
Rated output power |
600VA / 480W 1000VA / 800W _ _ _ |
Output power factor |
0 . 8 |
|
Output voltage |
220 VDC ± 5 % |
|
Output frequency |
50HZ ± 1.0 |
|
Dynamic Voltage Transient Range |
< 5% |
|
Dynamic Transient Response Recovery Time |
< 60 ms |
|
Output waveform distortion |
≤ 5 % (linear load ) |
|
Overload capacity |
When the output overload is below 110% of the rated power , no alarm will be given, and the inverter output will not be closed: When the output overload is between 110% and 125% of the rated power , the system will shut down after 125% ~ 150% of the rated power , the system will shut down after 10 s for protection; when the output overload is greater than 150% of the rated power , Immediate shutdown protection . |
|
Inverter efficiency |
≥ 82 % |
|
Output connection |
multifunctional socket |
|
Protection features |
Protection function |
Battery overvoltage and undervoltage, battery input reverse polarity protection, output overload protection, output short circuit protection, over temperature protection and solar module reverse polarity protection |
Insulation resistance M Ω ( 500 VDC ) |
≥ 50% inverter DC input to the chassis and inverter AC output to the chassis |
|
Output mode |
forced air cooling |
|
Audio noise dB (radius 1 meter away ) |
< 65 |
|
Operating environment |
Ambient temperature |
- 5°C ~ +40 °C |
Considerable humidity |
0 ~ 93% , non- condensing |
|
Altitude |
≤ 1000 meters |
|
Storage environment |
Storage temperature |
- 20℃ ~ + 70 ℃ |
Considerable humidity |
0 ~ 93% , non- condensing |
|
Chassis size ( mm ) ( L ❉ W ❉ H ) |
L 362 ❉ W 347 ❉ H 1 22 .3 |
RF Point provides ODM & OEM services for your product design modifications and manufacturing services with world class standards & minimal time to market!