WPVS Wind and Solar Hybrid Control Inverter Integrated Machine

  • PWM or MPPT control algorithm, maximum utilization of solar energy conversion efficiency
  • Integrated design of control, inverter and isolation
  • Pure sine wave output
  • Output transformer isolation, safe and stable
  • With mains input interface (optional)
  • Excellent overload capacity
  • Suitable for all kinds of electrical appliances
  • Battery intelligent charge and discharge management, temperature compensation
  • Perfect protection function, over current, short circuit, reverse connection, over temperature protection
  • LCD full screen display

Description

Item target

Specifications

Wind Turbine Input Characteristics

Open circuit voltage

≤ 1 00 V DC

Charging current

20A _ M ax

Unloading voltage

31 . 5 VDC ± 0 . 2VDC

Recovery voltage after unloading

27 . 5 VDC ± 0 . 2VDC

Unloading resistance value

1.7Ω ± 15%

Input connection method

Terminals

PV module input characteristics 

Open circuit voltage

≤ 50 V  DC

Charging current

20A _ M ax

Input connection method

Terminals

Charge and discharge characteristics

Rated battery voltage

24V _ DC

Controller efficiency

≥ 95 %

Equalizing voltage

28 . 2 VDC ± 0 . 2VDC

Float voltage

27 . 6 VDC ± 0 . 2VDC

Low battery alarm

22 . 0 VDC ± 0 . 2VDC

Battery low voltage protection

21 . 6 VDC ± 0 . 2VDC

Battery low voltage recovery

26 . 0 VDC ± 0 . 2VDC

Overcharge protection voltage

28 . 8 VDC ± 0 . 2VDC

Battery high voltage alarm

30 . 0 VDC ± 0 . 2VDC

Battery high voltage protection

31.5 VDC ± 0.2 VDC  ( Turn off the output after 60 s )

Battery high voltage recovery

31 . 5 VDC ± 0 . 2VDC

AC output characteristics

Rated output power

600VA / 480W 1000VA / 800W _ _ _

Output power factor

0 . 8

Output voltage

220 VDC ± 5 %

Output frequency

50HZ ± 1.0

Dynamic Voltage Transient Range

< 5%

Dynamic Transient Response Recovery Time

< 60 ms

Output waveform distortion

≤ 5 % (linear load )

Overload capacity

When the output overload is below 110% of the rated power , no alarm will be given, and the inverter output will not be closed: When the output overload is between 110% and 125% of the rated power , the system will shut down after

125% ~ 150% of the rated power , the system will shut down after 10 s for protection; when the output overload is greater than 150% of the rated power , Immediate shutdown protection .

Inverter efficiency

≥ 82 %

Output connection

multifunctional socket

Protection features

Protection function

Battery overvoltage and undervoltage, battery input reverse polarity protection, output overload protection, output short circuit protection, over temperature protection and solar module reverse polarity protection

Insulation resistance M Ω ( 500 VDC )

≥ 50% inverter DC input to the chassis and inverter AC output to the chassis

Output mode

forced air cooling

Audio noise dB  (radius 1 meter away )

< 65

Operating environment

Ambient temperature

- 5°C ~ +40 °C

Considerable humidity

0 ~ 93% , non- condensing

Altitude

≤ 1000 meters

Storage environment

Storage temperature

- 20℃ ~ + 70 ℃

Considerable humidity

0 ~ 93% , non- condensing

Chassis size ( mm ) ( L ❉ W ❉ H )

L 362 ❉ W 347 ❉ H 1 22 .3