Model |
WSPS 100 0 |
WSPS 200 0 |
WSPS 300 0 |
WSPS 400 0 |
WSPS 500 0 |
||
Output power |
1000W |
2000W _ _ |
3000W _ _ |
4000W _ _ |
500 0 W |
||
Wind Turbine Characteristics |
|||||||
Fan power |
400 W |
1000W _ _ |
1500W |
2000 W |
3000 W |
||
Working voltage |
1 00 V DC |
300 VDC |
|||||
Charging current |
8 . 0A |
20 . 0A |
7 . 0A |
10 . 0A |
23 . 0A |
||
Unloading voltage |
58 . 6 VDC |
264 . 0 VDC |
|||||
Unload recovery voltage |
55 . 2 VDC |
235.0 VDC |
|||||
Unloading resistance value |
5.6Ω |
2.24Ω± 0.3 |
31.0Ω±0.3 |
23.2Ω±0.3 |
15.5Ω± 0.32 |
||
Fan output AC |
Three-phase three- wire |
||||||
PV Input Characteristics |
|||||||
Input power |
600 wp |
1000 wp |
2000 wp |
2500 wp |
3000 wp |
||
Open circuit voltage |
1 50 . 0 VDC |
460 VDC |
|||||
Charging current |
12 . 0A |
20 . 0A |
8 . 0A |
10 . 0A |
12 . 0A |
||
DC characteristics |
|||||||
Battery voltage |
48 VDC |
220 VDC |
|||||
Conversion efficiency |
97 % |
||||||
Equalization charging voltage |
57.6VDC _ _ |
259.2 VDC |
|||||
Float voltage |
54.0 VDC |
243.0 VDC |
|||||
Undervoltage alarm |
43.2VDC _ _ |
198.0 VDC |
|||||
Overcharge protection |
58.8VDC _ _ |
264.0 VDC |
|||||
Overcharge recovery |
55.2 VDC |
253 . 0 VDC |
|||||
Output characteristics |
|||||||
Output power |
1 00 0 VA |
2000 VA |
3000 VA |
4000 VA |
5000 VA |
||
Power factor |
1 . 0 |
||||||
Output voltage |
220VAC ± 2 % |
||||||
Output frequency |
50 Hz ± 1.0 Hz |
||||||
Dynamic Voltage Transient Range |
≤ 3 % |
||||||
Transient response recovery time |
≤ 60ms |
||||||
Output voltage distortion |
≤ 3 % ( sine wave ) |
||||||
Overload capacity |
< 1 1 0 % continuous: ≥ 1 1 0 % ~ 125% for 60 s ; ≥ 125% ~ 150% , last 1 0 s ; ≥ 150% , second off |
||||||
Conversion efficiency |
85 % |
88 % |
89 . 0 % |
91 . 3 % |
93 . 0 % |
||
Output interface type |
Terminal block |
||||||
Protective properties |
|||||||
Protection function |
Battery overcharge, overdischarge , output overload, short circuit, overheating inside the machine, reverse polarity , etc. |
||||||
Environmental characteristics |
|||||||
Insulation resistance |
≥ 50 MΩ ( input to chassis, output to chassis ) |
||||||
Cooling method |
air cooled |
||||||
The noise |
≤ 55 days B ( distance 1 m ) |
||||||
Operating temperature range |
- 30℃ ~ +45 ℃ |
||||||
Humidity |
0 ~ 93% , no condensation |
||||||
Altitude |
≤ 2000m (reduced power usage ) |
||||||
Storage temperature |
- 50℃ ~ + 70 ℃ |
RF Point provides ODM & OEM services for your product design modifications and manufacturing services with world class standards & minimal time to market!